技術(shù)參數(shù) | |||
通道數(shù)量 | 96 | 通道間隔 | 50GHz, 100GHz |
通道頻率 | 196.45~191.7THz | 最大輸入功率 | 500mW; 27dBm |
帶寬 | 1526.05~1563.86 nm | 光源接頭 | SC/PC Standard |
測(cè)量速度 | 4 Sec. (all 96ch.) | 電池 | 鋰聚合物電池, 1800毫安時(shí),3.7伏 |
測(cè)量范圍 | +10~-40dBm | 電池工作時(shí)長(zhǎng) | 充滿電后單次使用620分鐘 |
測(cè)量精度 | ± 1.0dB @ -40 dBm | 電流消耗(Max) | 0.25A |
顯示屏分辨率 | 0.01dB | 電力消耗 | 0.925W |
顯示單位 | dB, dBm,nm,THz | 顯示 | 3.5” TFT-LCD, 16bit color, 240*320 |
重量 | 0.6 kg | 尺寸 | 196*95*40 mm |
溫度 (環(huán)境條件) | -20 to +55 °C (操作環(huán)境) | 濕度 (最大無(wú)冷凝) | 95% (操作環(huán)境) |
-35 to +65°C (儲(chǔ)存環(huán)境) | 85% (儲(chǔ)存環(huán)境) |
美國(guó)米頓羅GM系列機(jī)械隔膜式計(jì)量泵/GM0120米頓羅加藥泵/蘇州加藥泵
計(jì)量泵GM0050 /米頓羅GM0050/米頓羅計(jì)量泵GM0050/蘇州GM0050計(jì)量泵
GM0090米頓羅/GM0090計(jì)量泵/米頓羅計(jì)量泵GM0090/蘇州GM0090計(jì)量泵
米頓羅GM0120 /計(jì)量泵GM0120 /米頓羅計(jì)量泵GM0120/蘇州GM0120計(jì)量泵
米頓羅GM0170 /計(jì)量泵GM0170 /米頓羅計(jì)量泵GM0170/蘇州GM0170計(jì)量泵
GM0500米頓羅/GM0500計(jì)量泵/米頓羅計(jì)量泵GM0500/蘇州GM0500計(jì)量泵
主要型號(hào)包括:GM0050 GM0090 GM0120 GM0170 GM0240 GM0330 GM0400 GM0500
特點(diǎn):
平滑脈沖設(shè)計(jì),無(wú)沖擊 ? 沖程在靜態(tài)及動(dòng)態(tài)條件下均可調(diào)節(jié)
多種材質(zhì)及泵頭結(jié)構(gòu)可選 ? 可選配電動(dòng)沖程控制器
機(jī)械驅(qū)動(dòng)PTFE膜片 ? 最大液體溫度40 ℃*
手動(dòng)/ 自動(dòng)沖程調(diào)節(jié)可選 ? 穩(wěn)態(tài)精度 +/- 2%(10%~100%)
沖程可調(diào)0~100%(自動(dòng)/手動(dòng)) ? 最大吸程4m水柱*
可選配電機(jī)控制器實(shí)現(xiàn)外部信號(hào)自動(dòng) 控制, ? 最大吸入壓力:20m 水柱
電機(jī)頻率0~100%可調(diào)(GM泵 自動(dòng)控制方式)
米頓羅機(jī)械隔膜泵,GM和GB系列兩個(gè)系列。泵頭材質(zhì)為PVC,PP,SS316,高粘度等可選擇,適合多種場(chǎng)合液體介質(zhì)的輸送。流量范圍從2.25L到1800L均有。
可選雙隔膜泵頭結(jié)構(gòu)
建議維護(hù)周期: 自動(dòng)控制方式選擇
電動(dòng)沖程控制器接受外部控制信號(hào),調(diào)節(jié)計(jì)量泵沖程長(zhǎng)度, 從而改變計(jì)量泵輸出流量。
GM系列計(jì)量泵選擇ST型。 GB系列計(jì)量泵選擇ECC型。
變頻控制器:接受外部控制信號(hào),調(diào)節(jié)計(jì)量泵沖程頻率,從而改變計(jì)量泵輸出流量。
供 電:220V/50HZ 單向
380V/50HZ 三相 控制信號(hào):4~20mA 電機(jī)控制器(VARIPULSE):
僅用于GM系列計(jì)量泵,用于控制三相電機(jī),改變沖程頻率,從而調(diào)節(jié)計(jì)量泵輸出流量。
V 型-同計(jì)量泵一體式安裝 VR型-同計(jì)量泵分體式安裝
主要型號(hào)包括:GM0050 GM0090 GM0120 GM0170 GM0240 GM0330 GM0400 GM0500
上海 | 江蘇 | 浙江 | 安徽 | 福建 | 江西 | 山東 | 山西| 湖北 | 湖南 | 廣東 | 廣西 | 海南 | 重慶 | 四川 | 貴州 | 云南
蘇州米頓羅機(jī)械隔膜計(jì)量泵
1)*系列型號(hào)編碼 | 流量* L/h | 壓力 MPa | 沖程 spm |
GM0002PL1MNN GM0005PL1MNN GM0010PL1MNN | 2.25 4.5 9 | 1.2 1.2 1.2 | 36 72 144 |
GM0025PL1MNN GM0050PL1MNN | 25 50 | 1.2 1.0 | 72 144 |
GM0090PQ1MNN GM0120PQ1MNN GM0170PQ1MNN GM0240PP1MNN | 85 115 170 235 | 0.7 0.7 0.7 0.7 | 72 72 144 144 |
GM0330PP1MNN GM0400PP1MNN GM0500PP1MNN | 315 400 500 | 0.5 0.5 0.5 | 144 144 180 |
上海 | 江蘇 | 浙江 | 安徽 | 福建 | 江西 | 山東 | 山西| 湖北 | 湖南 | 廣東 | 廣西 | 海南 | 重慶 | 四川 | 貴州 | 云南
特點(diǎn):
•平滑脈沖設(shè)計(jì),無(wú)沖擊 •沖程在靜態(tài)及動(dòng)態(tài)條件下均可調(diào)節(jié)
•多種材質(zhì)及泵頭結(jié)構(gòu)可選 •可選配電動(dòng)沖程控制器
•機(jī)械驅(qū)動(dòng)PTFE膜片 •最大液體溫度40 ℃*
•手動(dòng)/ 自動(dòng)沖程調(diào)節(jié)可選 •穩(wěn)態(tài)精度±2%(10%~100%)
•沖程可調(diào)0~100%(自動(dòng)/手動(dòng)) •最大吸程4m水柱*
•可選配電機(jī)控制器實(shí)現(xiàn)外部信號(hào)自動(dòng) 控制,•最大吸入壓力:20m 水柱
電機(jī)頻率0~100%可調(diào)(GM泵 自動(dòng)控制方式)
•可選雙隔膜泵頭結(jié)構(gòu)
•建議維護(hù)周期:≤1.0MPa 4000h
≤0.7MPa 8000h
自動(dòng)控制方式選擇
•電動(dòng)沖程控制器 接受外部控制信號(hào),調(diào)節(jié)計(jì)量泵沖程長(zhǎng)度, 從而改變計(jì)量泵輸出流量。
GM系列計(jì)量泵選擇ST型。 GB系列計(jì)量泵選擇ECC型。
•變頻控制器: 接受外部控制信號(hào),調(diào)節(jié)計(jì)量泵沖程頻率,從而改變計(jì)量泵輸出流量。
供 電:220V/50HZ 單向
380V/50HZ 三相
控制信號(hào):4~20mA
•電機(jī)控制器(VARIPULSE):
僅用于GM系列計(jì)量泵,用于控制三相電機(jī),改變沖程頻率,從而調(diào)節(jié)計(jì)量泵輸出流量。
V 型-同計(jì)量泵一體式安裝
VR型-同計(jì)量泵分體式安裝
1Human cyclic adenosinemonophosphate(cAMP)Elisa KitCatalog No. CSB-E04488h(96T) This immunoassay kit allows for the in vitro quantitative determination of humancAMP concentrations in serum, plasma. Expiration date six months from the date of manufacture FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.2INTRODUCTIONCyclic adenosine monophosphate (cAMP, cyclic AMP or 3'-5'-cyclicadenosine monophosphate) is a second messenger important in manybiological processes. cAMP is derived from adenosine triphosphate (ATP)and used for intracellular signal transduction in many different organisms,conveying the cAMP-dependent pathway.cAMP is synthesised from ATP by adenylyl cyclase located on the innerside of the plasma membrane. Adenylyl cyclase is activated by a range ofsignaling molecules through the activation of adenylyl cyclase stimulatory G(Gs)-protein-coupled receptors and inhibited by agonists of adenylylcyclase inhibitory G (Gi)-protein-coupled receptors. Liver adenylyl cyclaseresponds more strongly to glucagon, and muscle adenylyl cyclase respondsmore strongly to adrenaline.cAMP decomposition into AMP is catalyzed by the enzymephosphodiesterase.cAMP is a second messenger, used for intracellular signal transduction,such as transferring the effects of hormones like glucagon and adrenaline,which cannot pass through the cell membrane. It is involved in theactivation of protein kinases and regulates the effects of adrenaline andglucagon. It also regulates the passage of Ca2+ through ion channels.3PRINCIPLE OF THE ASSAYThe microtiter plate provided in this kit has been pre-coated with agoat-anti-mouse IgG. Standards or samples are then added to theappropriate microtiter plate wells with a HRP-conjugated cAMP andantibody preparation specific for cAMP and incubated. Then substratesolutions are added to each well. The enzyme-substrate reaction isterminated by the addition of a sulphuric acid solution and the color changeis measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. Theconcentration of cAMP in the samples is then determined by comparing theO.D. of the samples to the standard curve.DETECTION RANGE0.08pmol/ml-250 pmol/ml. The standard curve concentrations used for theELISA’s were 250 pmol/ml, 50 pmol/ml, 10 pmol/ml, 2 pmol/ml, 0.4 pmol/ml,0.08 pmol/ml.SPECIFICITYThis assay recognizes human cAMP No significant cross-reactivity orinterference was observed.4MATERIALS PROVIDEDReagent QuantityAssay plate 1Standard1 x 0.25 ml(5000pmol/ml)HRP-conjugate 1(1000 x stock solution)Antibody 1(1000 x stock solution)HRP-conjugate Diluent 1 x 6 mlAntibody Diluent 1 x 6 mlNeutralizing Reagent 1 x 6 mlWash Buffer1 x 15 ml(10×concentrate)Substrate A 1 x 10 mlSubstrate B 1 x 10 mlStop Solution 1 x 6 mlOTHER SUPPLIES REQUIRED1. Deionized or distilled water.2. Concentrated HCl.3. Precision Pipets for volumes between 5μ l and 1000μ l.4. Repeater Pipets for dispensing 50μ l and 200μ l.5. Disposable breakers for diluting buffer concentrates.6. Graduated cylinders.7. A microplate shaker.8. Adsorbent paper for blotting.9. Microplate reader capable of reading at 450 nm, preferably withcorrection between 570 and 590 nm.5STORAGE1. For long-term best results, store stocks of the Standard ,Antibody andHRP-conjugate at -80℃. All other components of this kit are stable at4°C until the kit's expiration date.SAMPLE COLLECTION AND STORAGEThis ELISA is compatible with cAMP samples that have been treated withhydrochloric acid to stop endogenous phosphodiesterase activity. Samplesin this matrix can be measured directly without evaporation or furthertreatment.Tissue samples should be frozen in liquid nitrogen. The tissue should beground to a fine powder under liquid nitrogen in a stainless steel mortar.After the liquid nitrogen has evaporated, weigh the frozen tissue andhomogenize in 10 volumes of 0.1M HCl. Centrifuge at > 600 x g at roomtemperature. The samples can then be diluted in the 0.1M HCl.Cells grown in tissue culture media can be treated with 0.1M HCl after firstremoving the media. Incubate for 10 minutes and visually inspect the cellsto verify cell lysis. If adequate lysis has not occurred incubate for a further10 minutes and inspect. Centrifuge at 600 x g at room temperature, thenuse the supernatant directly in the assay. Cell or tissue lysis can beenhanced by adding 0.1% to 1% Triton x-100 to the 0.1M HCl prior to use.When used in this concentration range, the detergent will not interfere with6the binding portion of the assay, however there will be a modest increase inthe optical density. Samples containing Triton should be evaluated against astandard curve diluted in the same for the most accurate determination.Cyclic AMP in the media can be measured after treating 1 mL of thesupernatant media with 10 μ L of concentrated hydrochloric acid.Centrifuge at 600 x g at room temperature. The supernatants can then beused directly in the assay.Procedural Notes1. Allow all reagents to warm to room temperature for at least 30 minutesbefore opening.2. Pre-rinse the pipet tip with reagent ,use fresh pipet tips for eachsample,standard and reagent.3. Pipet standards and samples to the bottom of the wells.4. Add the reagents to the side of the well to avoid contamination.5. The kit uses break-apart microtiter strips,which allow the user tomeasure as many samples as desired.Unused wells must be keptdesiccated at 4℃ in the sealed bag provided,The wells should be usedin the frame provided.6. Prior to addition of substrate ensure that there is no residual washbuffer in the wells .Any remaining wash buffer may cause variationin assay resultes.REAGENT PREPARATIONBring all reagents to room temperature before use.71. Wash Buffer If crystals have formed in the concentrate, warm to roomtemperature and mix gently until the crystals have completely dissolved.Dilute 15 ml of Wash Buffer Concentrate into deionized to prepare 150ml of Wash Buffer.2. HRP-conjugate working solution: Centrifuge the vial right before use.Dilute the HRP-conjugate 1000x stock solution (take 6μl) with theprovided dilution buffers (6 ml).3. Antibody working solution: Centrifuge the vial right before use. Dilutethe Antibody 1000x stock solution (take 6μl) with the provided dilutionbuffers (6 ml).4. Standards: Centrifuge the vial right before use. Allow the 5,000pmol/mL cAMP standard solution to warm to room temperature. Labelsix tubes #1 through #6. Pipet 475 μL 0.1M HCl into tube #1 and 400 μL0.1M HCl into tubes #2-6. Add 25 μL of the 5,000 pmol/mL standard totube #1. Vortex thoroughly. Add 100 μL of tube #1 to tube #2 andvortex thoroughly. Continue this for tubes #3 through #6. Theconcentration of cAMP in tubes #1 through #6 will be 250, 50, 10, 2, 0.4,and 0.08 pmol/mL respectively. Diluted standards should be usedwithin 30 minutes of preparation. Label one tube as the ZeroStandard/NSB tube. Pipet 600μl 0.1M HCl into this tube.ASSAY PROCEDUREBring all reagents to room temperature for at least 30 minutes prioropening.ALL standards and samples should be run in duplicate.Add the reagen directly to the samples and vortex for 2 seconds immediatelyafter the addition.81. Refer to the Assay Layout Sheet to determine the number of wells to beused and put any remaining wells with the desiccant back into thepouch and seal the ziploc .Store unused wells at 4℃.2. Pipet 50 μL of the Neutralizing Reagent into each well, except theTA(Total Activity) and Blank wells.3. Pipet 100 μL of 0.1M HCl into the NSB(None Specific Binding) and theBo (0 pmol/mL Standard) wells.4. Pipet 100 μL of Standards into the appropriate wells.5. Pipet 100 μL of the Samples into the appropriate wells.6. Pipet 50 μL of 0.1 M HCl into the NSB wells.7. Pipet 50 μL of HRP-conjugate working solution into each well exceptthe TA and Blank wells.8. Pipet 50 μL of Antibody working solution into each well, except theBlank, TA and NSB wells.9. Incubate the plate at room temperature for 2 hours on a plate shaker at250~500 rpm.10. Empty the contents of the wells and wash by adding 400 μL of washsolution to every well. Repeat the wash 2 more times for a total of 3washes.11. After the final wash, empty or aspirate the wells, and firmly tap the plateon a lint free paper towel to remove any remaining wash buffer.12. Add 5 μL of the HRP-conjugate working solution to the TA wells.913. Add 200 μL of the Substrate solution to every well. Incubate at roomtemperature for 5~30 minutes without shaking. A gradient of blue colorshould become visible during the incubation period. (Substrate A andB should be mixed together in equal volumes within 15 minutes ofuse. Protect from light.)14. Add 50 μL of Stop Solution to every well. This stops the reaction andthe plate should be read immediately.15. Blank the plate reader against the Blank wells, read the optical densityat 450 nm (for HRP), preferably with correction between 570 and 590nm. If the plate reader is not able to be blanked against the Blankwells, manually subtract the mean optical density of the Blank wellsfrom all readings.1 0CALCULATION OF RESULTSSeveral options are available for the calculation of the concentration ofcAMP in the samples. The X-axis is the concentration of cAMP for thestandards. The Y-axis is either the Average Net Optical Density or thePercent Bound.1. Calculate the average Net Optical Density (OD) bound for each standardand sample by subtracting the average NSB OD from the average ODbound:Average Net OD = Average Bound OD - Average NSB OD2. Calculate the binding of each pair of standard wells as a percentage ofthe maximum binding wells (Bo), using the following formula:3. Using Logit-Log paper plot Average Net OD or Percent Bound(B/Bo) versus concentration of cAMP for the standards. Theconcentration of cAMP in the unknowns can be determined byinterpolation.1 1Typical Standard CurvesThese curves must not be used to calculate cAMP concentrations; eachuser must run a standard curve for each assay and version used.SensitivitySensitivity was calculated by determining the average optical density boundfor ten wells run with the Bo, and comparing to the average optical densityfor ten wells run with Standard #5. The detection limit was determined asthe concentration of cAMP measured at two standard deviations from thezero along the standard curve.Non-Acetylated VersionMean OD for Bo = 0.685±0.003Mean OD for Standard #5 = 0.604±0.010Delta Optical Density(0-0.08pmol/ml) = 0.0812 SD's of the Zero Standard = 0.006Sensitivity = ̄0.006/0.081×0.4pmol/ml = 29.6 fmol/mL1 2LinearityA sample containing 16.0 pmol/mL cAMP was serially diluted 7 times 1:2 inthe 0.1M HCl and measured. The data was plotted graphically as actualcAMP concentration versus measured cAMP concentration. The lineobtained had a slope of 1.000 with a correlation coefficient of 0.999.Cross ReactivitiesThe cross reactivities for a number of related compounds were determinedby competition ELISA assays. Potential cross reactants were dissolved inthe kit Assay Buffer at concentrations from 500,000 to 500 pmol/mL. Thesesampleswere then measured in the cAMP assay, and the measured cAMPconcentration at 50% B/Bo calculated. The % cross reactivity wascalculated by comparison with the actual concentration of cross reactant inthe sample and expressed as a percentage.Compound Cross ReactivitycAMP 100%AMP <0.0001%ATP <0.0001%cGMP <0.0001%GMP <0.0001%GTP <0.0001%cUMP <0.0001%CTP <0.0001%
HS706C.T.P4S.DUL軸承 HS706C.T.P4S.DUL軸承價(jià)格 HS706C.T.P4S.DUL軸承尺寸 HS706C.T.P4S.DUL軸承報(bào)價(jià) 精密角接觸球軸承樣本圖
訂購(gòu)原裝FAG軸承請(qǐng)撥打021-3653 9288【FAG HS706C.T.P4S.DUL軸承】尺寸規(guī)格參數(shù):軸承型號(hào):HS706C.T.P4S.DUL軸承軸承系列:精密角接觸球軸承軸承品牌:FAG軸承內(nèi)徑:6 外徑:17 厚度:6 動(dòng)載荷(Cr):1.56 靜載荷(Cor):0.7 脂潤(rùn)滑限速:150000油潤(rùn)滑限速:220000凈重kg:0.01 產(chǎn)品描述:鋼球,15度,樹脂保持架,P4級(jí),開式,對(duì)裝自由配組 上海東晟軸承有限公司提供 HS706C.T.P4S.DUL軸承的軸向壓力、滾粒的數(shù)目、動(dòng)態(tài)負(fù)荷、靜態(tài)負(fù)荷、直徑、替代型號(hào)等技術(shù)參數(shù),我公司代理經(jīng)營(yíng)美國(guó)FAG軸承,瑞典SKF軸承,日本 NSK、NTN、IKO軸承,德國(guó)FAG、INA軸承、NADELLA軸承等名優(yōu)進(jìn)口軸承,如果您對(duì) 6 mm×17 mm×6 mm FAG HS706C.T.P4S.DUL軸承有疑問(wèn),請(qǐng)聯(lián)系我們獲取更多HS706C.T.P4S.DUL軸承的最新信息。TEL:021-3653 9288 我公司專業(yè)現(xiàn)貨供應(yīng)精密角接觸球軸承 HS706C.T.P4S.DUL軸承,我們?yōu)槟扑]以下型號(hào): B7004-E-T-P4S軸承 R18/16-8 23096BKD1 NN3026軸承 PHS3EC HC7004-C-T-P4S軸承 7036CD/DT W036 6320-2Z軸承 4T-HM911242/HM911210 6301-2RZ軸承 6016-RS1 2207K NA4826軸承 SD544 FAG HS706C.T.P4S.DUL軸承 我公司還為您推薦FAGHS706C.T.P4S.DUL軸承廣泛應(yīng)用于: 齒輪泵, 手動(dòng)泵, 釘跟機(jī), 玻璃反應(yīng)釜, 移印機(jī), 食品藥品包裝機(jī), 化纖機(jī)械, 塑料板材設(shè)備, 氣流干燥設(shè)備, 等領(lǐng)域。EGBZ0812-E40軸承 http://www.fag.sh.cn/zhoucheng/EGBZ0812-E40.htmlEGBZ0814-E40軸承 http://www.fag.sh.cn/zhoucheng/EGBZ0814-E40.htmlC081008軸承 http://www.fag.sh.cn/zhoucheng/C081008.htmlBCE85軸承 http://www.fag.sh.cn/zhoucheng/BCE85.htmlK20X26X12軸承 http://www.fag.sh.cn/zhoucheng/K20X26X12.htmlL812147/L812111軸承 http://www.timken.sh.cn/TIMKEN/L812147_L812111.htmlL812148/L812111軸承 http://www.timken.sh.cn/TIMKEN/L812148_L812111.html29590/29520軸承 http://www.timken.sh.cn/TIMKEN/29590_29520.html29590/29522軸承 http://www.timken.sh.cn/TIMKEN/29590_29522.html395A/394軸承 http://www.timken.sh.cn/TIMKEN/395A_394.htmlEWP211軸承 http://www.nsk.sh.cn/bearings/EWP211.htmlEWP212軸承 http://www.nsk.sh.cn/bearings/EWP212.htmlEWP305軸承 http://www.nsk.sh.cn/bearings/EWP305.htmlAX4.5120155軸承 http://www.nadella.sh.cn/bearings/AX4.5120155.html
一、PXR型數(shù)字溫控表的功能特點(diǎn)如下: 1. 前面板IP66防水結(jié)構(gòu),三健式菜單操作;2.標(biāo)準(zhǔn)螺釘接線,無(wú)須插座;3. 縱向尺寸比PXW表更短;4. UL/CSA/CE認(rèn)證標(biāo)志;5. 測(cè)量值大LED紅色顯示;6. 控制功能多種:簡(jiǎn)單ON/OFF控制,PID帶自動(dòng)調(diào)節(jié)控制,模糊及PID帶自動(dòng)調(diào)節(jié)控制,PID自適應(yīng)調(diào)節(jié)控制;7.再傳輸功能(選件):傳感器測(cè)量值可以以4-20MA型式傳送到PHR型數(shù)據(jù)記錄儀,PLC及個(gè)人計(jì)算機(jī)中;8.8段斜坡/保溫程序控制功能(選件);9.RS-485通訊功能(選件),可與FUJI POD及個(gè)人計(jì)算機(jī)通訊;10.?dāng)?shù)字輸入控制功能(選件):通過(guò)一點(diǎn)開關(guān)量ON/OFF,可改變?cè)O(shè)定值SV,控制動(dòng)作起/停,斜坡/保溫控制的開始/ 復(fù)位,自動(dòng)調(diào)節(jié)功能的起/停,報(bào)警鎖存的復(fù)位、定時(shí)器計(jì)時(shí)開始;11. 加冷卻控制(選件):有利于節(jié)能;12. 加熱斷線報(bào)警(選件);13. 兩點(diǎn)各種報(bào)警功能(選件):絕對(duì)值報(bào)警區(qū)間報(bào)警偏差報(bào)警; 14. 具有塑機(jī)專用的模糊+PID控制功能:15. 內(nèi)部定時(shí)器功能二、型號(hào)及尺寸PXR3 24×48×97 (高×寬×深)PXR5 96×48×78 (高×寬×深)PXR4 48×48×78.8 (高×寬×深)PXR9 96×96×79.5(高×寬×深)技術(shù)指標(biāo)控制類型: PID 控制、on/off控制、自整定、模糊控制單輸出或加熱/制冷雙
最大32K的超大內(nèi)存,3軸100K的高速脈沖具體型號(hào)如下:FX3G-14MTFX3G-24MT 最多可以帶二個(gè)擴(kuò)展模塊FX3G-40MR FX3G-40MTFX3G-60MR FX3G-60MT 最多可以帶4個(gè)擴(kuò)展模塊
此外本機(jī)帶有USB接口可以直接帶FX2N的擴(kuò)展模塊可以直接帶FX3U的模塊擴(kuò)展模塊FX3U-232ADPFX3U-4AD-ADPFX3U-4DA-ADPFX3U-4AD-PT-ADPFX3U-4AD-PTW-ADP(寬溫度范圍)可以同時(shí)接2個(gè)通信接口,通信接口是:FX3G-232;422;485 例如 FX3G-232-BD+FX3G-485-BD
功率配置590+ 四象限逆變回饋型;2 個(gè)全控3 相晶閘管橋;591+ 二象限非逆變回饋型;1 個(gè)全控3 相晶閘管橋;晶閘管控制可變磁場(chǎng)電樞電流(ADC)規(guī)格1:15,35A規(guī)格2:40,70,110,165A規(guī)格3:180,270A規(guī)格4:380,500,725,830A規(guī)格5:1580A規(guī)格H:1200,1700,2200,2700ADRV 選項(xiàng)適用于尺寸規(guī)格1 和2。過(guò)載能力:電流為15-450A 的傳動(dòng),200% 過(guò)載最長(zhǎng)10 秒鐘;150%過(guò)載,最長(zhǎng)30 秒鐘。大于700A 的規(guī)格,不同規(guī)格有不同的過(guò)載能力。請(qǐng)參見手冊(cè)。電樞電壓:Varmature(max)=Vac x 1.2供電電源:110-220V(± 10%),規(guī)格1-5 選項(xiàng)220-500V(± 10%),規(guī)格1-5500-600V(± 10%),規(guī)格4-5 選項(xiàng)500-690V(± 10%),規(guī)格H磁場(chǎng)電流規(guī)格1:4A 規(guī)格2-3:10A規(guī)格4-5:30A 規(guī)格H:60A磁場(chǎng)電壓:Vfield(max)=Vac x 0.9環(huán)境溫度:0-45℃,< 270A 的規(guī)格;0-40℃,> 270A 的規(guī)格。超過(guò)上限,溫度每升高1℃,降容1% 。環(huán)境溫度為55℃海拔:500 米以下正常使用;超過(guò)500 米,每升高200 米,降容1%;為5000 米。
模擬輸入:5 個(gè)(1 個(gè)12bits 精度帶符號(hào),4 個(gè)10bits 精度帶符號(hào))1 速度給定 (-10/0/+10V);4 可自定義模擬輸出:3 個(gè)(10bits A/D 轉(zhuǎn)換精度)1 電樞電流輸出(-10/0/+10V 或0-10V)2 可自定義數(shù)字輸入:9 個(gè)(24VDC,最大15A)1- 程序控制停止1- 慣性停車1- 外部信號(hào)停車1- 啟停5- 可自定義數(shù)字輸出:3 個(gè)(24V(最大30V) 100mA)3- 可自定義參考電壓輸入:3 個(gè),-10VDC/+10VDC/24VDC保護(hù)高能Mov"s 散熱器過(guò)溫瞬時(shí)過(guò)流晶閘管觸發(fā)失敗逆變過(guò)流線間緩沖器網(wǎng)絡(luò)磁場(chǎng)故障零速監(jiān)測(cè)速度反饋故障靜止邏輯電機(jī)過(guò)熱堵轉(zhuǎn)保護(hù)標(biāo)準(zhǔn):符合歐洲CE 和北美UL 的工業(yè)標(biāo)準(zhǔn)。
如有需要請(qǐng)?jiān)赒Q上留言,謝謝!
EH-50P電磁流量計(jì)由儀華測(cè)控生產(chǎn),質(zhì)量可靠,售后有保障。聯(lián)系人:吳先生;聯(lián)系電話:傳真,QQ908805187本文來(lái)源<p><strong><a >壓力變送器</a></strong></p>,http://www.yhck88.com/,<p><strong><a >壓力變送器,<p><strong><a >壓力變送器</a></strong></p>產(chǎn)品名稱:EH-50P電磁流量計(jì)規(guī)格型號(hào):可非標(biāo)定制產(chǎn)品價(jià)格:不同型號(hào)價(jià)格不同,請(qǐng)來(lái)電資詢產(chǎn)品類別:流量計(jì)公司簡(jiǎn)介:儀華測(cè)控儀表有限公司主要生產(chǎn)各種型號(hào)的壓力變送器、壓力傳感器、物位計(jì)、料位計(jì)、磁翻板物位計(jì)、溫度儀表、壓力儀表、物位儀表、控制開關(guān)、電熱帶配件等產(chǎn)品。是歷史三十多年的儀表儀器行業(yè)中的大型企業(yè),被國(guó)家列入大型一檔企業(yè),并被例入中國(guó)電力企業(yè)家協(xié)會(huì)火電分會(huì)成員,化工產(chǎn)業(yè)定點(diǎn)企業(yè)。被化工部、機(jī)電部、冶金工業(yè)部推薦為質(zhì)量信得過(guò)產(chǎn)品企業(yè)。由于儀華的誠(chéng)信和努力,長(zhǎng)期來(lái)在供求雙方之間保持著很高的信譽(yù)和良好的溝通渠道。企業(yè)連續(xù)多年被有關(guān)部門評(píng)為“重合同,守信用”單位。 興化儀華生產(chǎn)EH-50P電磁流量計(jì)傳感器由LDCK型EH-50P電磁流量計(jì)傳感器和TBS型M900電磁流量傳感器配套組成,用于測(cè)量管道內(nèi)液體流量,EH-50P電磁流量計(jì)可以測(cè)量酸、堿、鹽等腐蝕性液體或液體內(nèi)混有固體的兩相體,如礦漿、泥漿和含有大量雜物的污水及粘度很大的介質(zhì)。EH-50P電磁流量計(jì)具有測(cè)量精度不受介質(zhì)壓力、溫度、密度(包括固液比)、粘度等物理參數(shù)變化的影響,儀表靈敏、測(cè)量范圍度大的特點(diǎn),抗干擾能力強(qiáng),零點(diǎn)穩(wěn)定,工作可靠。EH-50P電磁流量計(jì)傳感器有防爆型,防爆等級(jí)為:mdⅡBT4。本產(chǎn)品執(zhí)行檢定規(guī)程:JJGl98-94速度式流量計(jì)檢定規(guī)程。EH-50P電磁流量計(jì)傳感器特點(diǎn):1、EH-50P電磁流量計(jì)可編程頻率低頻矩形波勵(lì)磁,提高了流量測(cè)量的穩(wěn)定性,功率損耗低;2、采用16位嵌入式微處理器,運(yùn)算速度快、精度高;3、EH-50P電磁流量計(jì)全數(shù)字量處理,抗干擾能力強(qiáng)。測(cè)量可靠,精度高,流量測(cè)量范圍可達(dá)1500:1;4、超低EMI開關(guān)電源,適用電源電壓變化范圍大?笶MC性能好;5、全漢字菜單操作,使用方便,操作簡(jiǎn)單,易學(xué)易懂;6、EH-50P電磁流量計(jì)高清晰度背光LCD顯示;7、具有雙向流量測(cè)量、雙向總量累計(jì)功能,電流、頻率具備雙向輸出功能;8、EH-50P電磁流量計(jì)內(nèi)部具有三個(gè)積算器可分別顯示正向累計(jì)量、反向累計(jì)量及差值積算量;9、EH-50P電磁流量計(jì)具有RS485或RS232C數(shù)字通訊信號(hào)輸出;10、EH-50P電磁流量計(jì)具有電導(dǎo)率測(cè)量功能,可以判別傳感器是否空管; 11、恒流勵(lì)磁電流范圍大,可與不同公司、不同類型的EH-50P電磁流量計(jì)傳感器配套使用;EH-50P電磁流量計(jì)傳感器具有自檢與自診斷功能;采用SMD器件和表面安裝(SMT)技術(shù),電路可靠性高;儀表內(nèi)部設(shè)計(jì)有不掉電時(shí)鐘,可記錄16次掉時(shí)間。
防護(hù)等級(jí): 標(biāo)準(zhǔn)型IP65,特殊型IP67 電 源: 轉(zhuǎn)換器電源220V,50Hz,傳感器由轉(zhuǎn)換器供電,(24V DC,特殊訂貨)。
V錐流量計(jì)須知(1)被測(cè)介質(zhì) (2)最大、常用、最小流量。 。3)工作壓力、工作溫度 。4)介質(zhì)密度、粘度 。5)管道材質(zhì)、內(nèi)徑、外徑 。6)允許壓力損失 。7)取壓方式 。8)現(xiàn)場(chǎng)管道敷設(shè)情況和局部阻力件形式
購(gòu)買渦輪流量計(jì)須知:1.認(rèn)真核對(duì)被測(cè)介質(zhì)的工況條件如:壓力、溫度、密度等。2.認(rèn)真核對(duì)被測(cè)介質(zhì)的流量范圍,確認(rèn)最小流量值并確定儀表口徑。3.確定傳感器的安裝地點(diǎn)。4.認(rèn)真天蝎訂貨咨詢單。5.與銷售部聯(lián)系,確認(rèn)選型的準(zhǔn)確性。
購(gòu)買EH-50P電磁流量計(jì)須知:1.認(rèn)真核對(duì)被測(cè)介質(zhì)的工況條件如:壓力、溫度、密度等。2.認(rèn)真核對(duì)被測(cè)介質(zhì)的流量范圍,確認(rèn)最小流量值并確定儀表口徑。3.確定傳感器的安裝地點(diǎn)。4.認(rèn)真天蝎訂貨咨詢單。5.與銷售部聯(lián)系,確認(rèn)選型的準(zhǔn)確性。
購(gòu)買EH-50P電磁流量計(jì)須知:1、認(rèn)真核對(duì)被測(cè)介質(zhì)的工況條件:壓力、溫度、密度等。2、認(rèn)真核對(duì)被測(cè)介質(zhì)的流量范圍,確認(rèn)最小流量值并確定儀表口徑。3、與生產(chǎn)廠銷售部聯(lián)系,確認(rèn)選型的準(zhǔn)確性。
購(gòu)買EH-50P電磁流量計(jì)須知:質(zhì)量流量計(jì)訂貨須知訂貨時(shí)請(qǐng)?jiān)敿?xì)提供以下數(shù)據(jù):(1)被測(cè)介質(zhì)(2)最大、常用、最小流量。(3)工作壓力、工作溫度(4)介質(zhì)密度、粘度(5)管道材質(zhì)、內(nèi)徑、外徑(6)允許壓力損失(7)取壓方式(8)現(xiàn)場(chǎng)管道敷設(shè)情況和局部阻力件形
購(gòu)買EH-50P電磁流量計(jì)須知:超聲波流量計(jì)訂貨須知測(cè)量氣體種類、成份及大致描述工況參數(shù)(溫度、壓力、流量范圍、密度)管道形式、材質(zhì),外徑及壁厚換能器安裝形式、位置,是否防爆,是否管段式轉(zhuǎn)換器安裝方式連接電纜長(zhǎng)度斷流安裝還是不斷流安裝,是否需要提供現(xiàn)場(chǎng)服務(wù)可選: 1、溫度、壓力變送器進(jìn)行補(bǔ)償,以及可編程(天然氣)流量積算儀
儀器采用LED顯示,有自動(dòng)和手動(dòng)(腳踏)兩種工作模式,超聲時(shí)間、功率任意設(shè)定,樣品溫度檢測(cè)顯示,頻率自動(dòng)跟蹤等功能。適用于小體積樣品處理的超聲波細(xì)胞破碎儀。
特點(diǎn):
可用于96酶標(biāo)及無(wú)數(shù)個(gè)小試管排列后,手持超聲波換能器點(diǎn)動(dòng)控制超聲,使無(wú)數(shù)個(gè)樣品在短時(shí)間內(nèi)完成超聲處理。
型號(hào) | UP-400S |
最大超聲功率輸出 | 400W |
主機(jī)尺寸 | 190*190*73mm |
控制模式 | 自動(dòng)、手動(dòng)可切換(可選配腳踏開關(guān)) |
溫度控制 | 超聲保護(hù)報(bào)警功能(0-99℃) |
脈沖器 | 0.1-99s可調(diào)(間隙/工作) |
工作頻率范圍 | 19-25KHz |
總時(shí)間 | 0.1-240min可設(shè)定 |
變幅桿 | 3mm |
處理量 | 10-200ml |
電源 | 220V/50Hz |