Acc3-6數(shù)顯計(jì)長(zhǎng)測(cè)速控制儀適用于印刷、包裝、紡織、食品化工等行業(yè)。用于自動(dòng)檢測(cè)產(chǎn)品數(shù)量,產(chǎn)品長(zhǎng)度。且可配套以相應(yīng)裝置實(shí)現(xiàn):定位換向、液位控制、尺寸控制、轉(zhuǎn)速測(cè)定,從而實(shí)現(xiàn)工業(yè)生產(chǎn)過程中的自動(dòng)控制之目的。![]() | |
![]() | |
![]() | |
![]() | |
![]() |
|
激光甲烷遙測(cè)檢測(cè)儀SA3C50A
一、概述◆ 天燃?xì)庠系男孤┙o企業(yè)帶來巨大的經(jīng)濟(jì)損失◆ 天燃?xì)庑孤⿴砹税踩[患◆ 遍布廠區(qū)的天燃?xì)夤艿罊z測(cè)費(fèi)工費(fèi)時(shí)◆ 高空管道/狹窄區(qū)域管道難以檢測(cè)◆ 泄漏點(diǎn)難以準(zhǔn)確定位二、檢測(cè)原理激光甲烷探測(cè)器基于紅外吸收分光檢測(cè)原理,使用激光二極管作為光源。 由于激光可被甲烷進(jìn)行吸收,測(cè)量時(shí),將探測(cè)器指向目標(biāo)探測(cè)物如管道、地表,通過接收被反射回來的激光束來測(cè)量激光束的吸收系數(shù),從而實(shí)現(xiàn)檢測(cè)甲烷堆或泄漏的目的。探測(cè)器采用柱體密度(即甲烷密度PPM乘以甲烷柱體高度M) 作為測(cè)量單位。
相關(guān)儀,聽漏儀,管線定位儀,供水管道泄漏檢測(cè)設(shè)備,燃?xì)庑孤z測(cè)儀,電纜故障測(cè)試儀,排水管道檢測(cè)儀,管道泄漏檢測(cè),燃?xì)夤艿佬孤z測(cè),燃?xì)鈾z測(cè)車,燃?xì)馐滞栖嚈z測(cè),防腐層檢測(cè)儀,管線探測(cè),管線普查,管線物探,管線定位,電纜檢測(cè),電纜故障檢測(cè)檢測(cè)儀,耐壓測(cè)試儀,防腐檢測(cè),埋地管道外防腐層檢測(cè)儀,管道檢測(cè),非開挖導(dǎo)向,電纜燒弧儀,地質(zhì)雷達(dá),清污車,清污設(shè)備,管道探測(cè),在線檢測(cè),內(nèi)窺檢測(cè),管道疏通,測(cè)漏儀,管道機(jī)器人,管道內(nèi)窺鏡,測(cè)漏,燃?xì)鈾z測(cè)儀,乙烷辨識(shí)儀,色譜分析儀,管道內(nèi)窺,切管機(jī),高壓測(cè)試儀,電纜測(cè)試車,管道檢測(cè),檢漏儀,電纜故障定位,電纜測(cè)試設(shè)備,爬行器,檢測(cè)儀,應(yīng)急檢漏,漏水檢測(cè)工程,路面鉆孔機(jī),路面打孔機(jī),路面開孔機(jī)
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley .
4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6. The substrate evade the light preservation.
7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. Do not mix reagents with those from other lots.
1.內(nèi)裝免維護(hù)充電蓄電池,充電可同時(shí)開機(jī)使用。2.開機(jī)自動(dòng)置零。3.零點(diǎn)自動(dòng)跟蹤。4.累計(jì)次數(shù)1~100次。5.電源:交流220V(+10%、-10%),50Hz,內(nèi)置6V/4Ah免維護(hù)可充電蓄電池。6.工作溫度范圍:0℃~+40℃。7.相對(duì)濕度≤ 85%RH。